Maintenance

Defects, leaks and equipment status, seen early. Each one becomes an alert, an assigned task and a photo-verified close-out.

Maintenance use cases
CodeUse caseWhat SensZ Eye watches forOperational benefit
MNT-01Water leakageNew water around pipe/equipment/ceiling areaEarly leak detection and reduced damage
MNT-02Pipe leakVisible dripping or water accumulationFaster maintenance response
MNT-03Ceiling leakNew stain, dripping, water accumulationEarly building defect detection
MNT-04Air-conditioning water leakWater near FCU/AHU/drain areaPrevents property damage
MNT-05Plant room floodingWater accumulation on plant room floorEarly warning and escalation
MNT-06Pump conditionIndicator/status light changeRemote monitoring without frequent rounds
MNT-07Equipment warning lightGreen/normal light changes to red/amberCreates maintenance task immediately
MNT-08Control panel statusVisual alarm or status changeReduces manual panel inspections
MNT-09Gauge reading exceptionNeedle/display outside expected visual rangeEnables condition-based maintenance
MNT-10Equipment running statusVisual indicator shows ON/OFF unexpectedlyFaster fault detection
MNT-11Lift fault indicationFault/status indicator appearsFaster escalation to lift contractor
MNT-12Escalator obstructionObject left at entrance/exitImproves passenger safety
MNT-13Escalator conditionVisible abnormality or stopped stateFaster response
MNT-14Door malfunctionDoor remains open/closed abnormallySupports access and maintenance teams
MNT-15Automatic door blockageObject blocking door pathFaster corrective action
MNT-16Fire door conditionFire door left open or obstructedImproves fire-safety compliance
MNT-17Emergency exit obstructionObjects blocking exit routeImmediate safety task
MNT-18Electrical room obstructionItems stored in restricted areaImproves compliance
MNT-19Switchboard obstructionMaterials placed in front of panelMaintains safe access
MNT-20Server/IT room water leakVisible water near equipmentReduces critical equipment risk
MNT-21Generator room conditionLeak, obstruction or visible status changeSupports preventive maintenance
MNT-22Battery room conditionSpill, obstruction or abnormal conditionImproves inspection efficiency
MNT-23Loading dock door statusDoor left open beyond expected periodEnergy/security benefit
MNT-24Damaged ceiling panelMissing/displaced ceiling tileFaster defect reporting
MNT-25Damaged wallNew visible damageSimplifies defect detection
MNT-26Broken glassVisible damaged glass/panelFaster safety response
MNT-27Damaged signageMissing/fallen/misaligned signsMaintains building standards
MNT-28Loose floor matMat moved, folded or displacedReduces trip hazard
MNT-29Obstructed drainDebris covering floor drainPrevents local flooding
MNT-30Drain overflowWater rising/overflowing around drainEarly flood response
MNT-31Sump pit levelAbnormal visible water levelReduces manual checks
MNT-32Tank levelVisual level above/below desired conditionAutomated inspection
MNT-33Utility meter inspectionCapture/display reading periodicallyReduces manual meter rounds
MNT-34Asset visual inspectionVisible change from baseline conditionSupports preventive maintenance
MNT-35Contractor work verificationBefore/after visual evidenceConfirms work completion